Tender For corrigendum : supply of low voltage mccb with thermal magnetic/electronic trip unit conforming to is/iec 60947 (part 2) (q3) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q3)
Tender For provision of 01 x 30 kva genr with connected items as standby power requirements for sewage treatment plant under age (i) bhalra - supply, installing, commissioning and testing, water cooled, sound proof silent type, turbo charged, diesel engine driven generating set 30 kva (at 0.8 pf), 415v, 3 phase, 4 wire engine as per is: 10001/10002 and alterator as per is: 13364, complete with relay panel for automatic starting on mains failure, control panels having meters in an integral acoustic enclosure as per recommendation cpcb norms, comprising of the following:notes: quoted rates shall deemed to include the following also:-(i) supply of t and p and normal space ie., bi-hexagonal ring spanner set of 12 pieces - 01 set.(ii) fuel measuement gauge - 01 no, hand operated fuel lifting pump with steel pipe 40mm dia - 01 no, hydro meter - 01 no, set of fan belt, oil/ fuel filters initial filling of coolant (coolant-2liters).(iii) service maintenance manual along with cat part list and price list - 03 set each.(iv) make of engine and alternator will be got approved from age (i) bhalra before placing the order., (a) diesel engine. diesel engine developing suitable bhp, 1500 rpm inclusive of the following standard accessories:(i) radiator/ heat exchanger cooling system. (xiv) battery charging generator.(ii) spider coupling guard. (xv) industrial silencer.(iii) fly wheel. (xvi) lubricant oil cooler.(iv) fly wheel housing complete with starter gear ring and coupling. (xvii) flexible pipe for silencer. (v) fuel pipes. (xviii) battery volt meter.(vi) air cleaner. (xix) water temperature gauge, lub oil pressure (vii) fuel and lubricant oil filter. gauge.(viii) by pass filter. (xx) speedo meter and engine running hours meter.(ix) coolant inhibitor. (xxi) display for fault.(x) fuel pump. (xxii) turbo charger.(xi) water pump. (xii) lubricant oil pump.(xiii) self/electric starter.(b) alternator : synchronous alternator 3 phase 4 wire, 50 cycles 1500 rpm, self excited, self regulated, brushless type, 0.8 pf, 415v, ac supply, 30 kva capacity, copper wound, complete including necessary tools, mounted on strong rigid steel fabricated base frame and directly coupled through flexible coupling with diesel engine, complete all as specified and directed., (c) amf/ control panel : amf panel factory made of suitable capacity as per original equipment manufacturer make and specification or as approved by oem for dg set of capacity 30 kva of suitable size, indoor cubical type, front and back openable fabricated out of mild steel sheet 1.6mm thick grounted in floor with adequate pcc foundation and minimum consisting of following :(i) contactor of suitable size for 30 kva dg set.(ii) copper bus bar of suitable current rating and sensitivity relay set unit with auxiliary cts.(iii) electronic latch circuit with tripping indication.(iv) re-set facilities.(v) 3 phase mvr relay unit with single phase protection complete with 2 no nc auxiliary contacts.(vi) 3 phase avr relay unit complete.(vii) self sequential starting relay unit 12 volts dc complete with alarm and power contactor. (viii) electronic timer 220 volts for main contactor with 1 no nc auxiliary contactor.(ix) electronic timer 220 volts for fuel cut off operation with 1 no auxiliary contactor.(x) battery charging 2x12 volts 10 amp complete with digital voltmeter and amps meter, including trickle and boost charging, make : su-kam, amco, exide or any other make as recommended by the manufacturer.(xi) volt meter 0-500 volts panel mounting of size 96mm square with selector switch digital type.(xii) amps meter 0-100 amps with 3 nos cts, 400/5 and selector switch 96 mm square digital type.(xiii) frequency meter (45-55) hz, 415 volt, 96mm square digital type.(xiv) the amf panel should have manual by pass arrangement too in case of failure of amf panel., (d) fuel tank of capacity as per manufacturer recommendations.(e) base frame made out of suitable channel duly reinforced and provided with adequate numbers of anti
Tender For corrigendum : complete rewiring including supply of required material of existing office, sheds of ph 2 inside ph premises for utilizing office setup for 1x660 mw supercritical extension unit no. 12 at stps, sarni. - work part, point wiring for bulb / tube point with 2.5 sq. mm pvc insulated cable alluminium conductor for., a) medium point, b) long point, c) special point, point wiring for fan point with 2.5 sq. mm pvc insulated cable alluminium conductor for long point ., point wiring for 5 amp, 5 pin socket for medium point., point wiring for call bell point with 2.5 sq. mm pvc insulated cable alluminium conductor for long point ., wiring for circuit wiring with pvc insulated with alluminium conductor.a) 60 x 2.5 sq. mm. (30 circuit), point wiring for 15 amp, 5 pin socket outlet point on separate board with 4 sq. mm. pvc insulated with alluminium conductor with gi earthing. wire, removal of old / damaged wiring point with wooden board & batten & main switch., t/l fitting on pvc square box complete with connection & testing., installation of mcbs enclosure, d.p. mcbs and sp mcbs, installation of 63 amp ictpn main switch., installation of 200 amp ictpn main switch, supply part, supply of single pole 32 amp mcb s, supply of double pole, 32 amp mcb s., supply of 24 way mcb s steel enclosure double door, supply of 63 amp. ictpn tripple pole 415v, supply of 2x2 led false ceiling lighting panel, supply of 20/22 watt , led tubelight fittings, supply of single phase, 300 mm, 1400 rpm exhaust fan in steel frame body, supply of electronic ceiling fan socket type regulator, supply 63 amp 10ka four pole mcbs., supply of 8 way mcb s steel enclosure double door., supply of tripple pole with neutral link switch fuse unit 415 v, 200 amp tpn.
Tender For bid to ras supply of mouse data entry , potential meter assy , panel electronic circuit comp acce h w c dimm comm , comp acce h w cpu dimm , dc dc converter
Tender For supply of electrical materials for the repair and maintenance of street light as per the boq - details, t-5 power/energy saver 2x24w choke, t-5 power/energy saver 24w ftl tuberod, 2x24 t5-holder, t5 power saver 2x24 fixture acrylic transparent cover, t5 power saver 4x24 fixture acrylic transparent cover, 150w hpsv choke, 150w hpsv lamp, capacitor 33mfd 250vac 50 hz, electronic ignitor suitable for 150w hpsv lamps, 150w holder (porcelain), led driver 50w bis certified, led mcpcb plate 60w, led mcpcb plate 50w, led mcpcb plate 150w, supplyingof isi marked and approved make of moulded case circuit breaker(mccb) suitable for 3phase,3pole,50hz,415 volts, ac supply with respective interrupting capacity(ka) at 415 volts cited against their range standard conforming to is - 8828: 8.1mccb with breaking capacity 25 ka at 415 v: current rating -125 amps & 70% -100% adjustable, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light sub feeder panels - type 2 pluggable spd 3+1, rating l-n/n-pe uc 255/320 v in 30/60ka ka, lmax 30ka/60 ka, up 1.5kv, supplying of isi marked and accepted standard of miniature circuit breaker(mcb)ofcseries suitable for 240/415volts,50cycle,10ka value ac supply confirming to is:8828:1996,iec:60898 :2002 but without enclosures: single pole 63 amp., astronomical timer with dst feature, contactor 3 pole 90 amp 50hz 415volts with no-nc contacts, tpn connector 150a, supply of approved make powder coated sheet steel encloser spn mcb db inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator): 8 way double door, supply of sovp device should have single high capacity varistor in the l-n plug and encapsulated spark gap for n-pe, l-n sovp should have a rated voltage of minimum 320v ac to handle indian power supply conditions. sovp should have visual indication on replaceable varistor and spark gap modules as well as a potential free contact on the socket for remote indication. sovp device should be wired up as per tt configuration of wiring in accordance with en 61643-11 standards. both the l-n and n-pe, spds should be rated for handling 30ka of nominal 8/20 s surge current.: sovp for pole light - type 2 pluggable spd 1+1, rating l-n/n- pe uc 230/400 v in 5 ka, imax 10 ka, up 1.2kv, led batten tubelight 20w, supplying of approved make tpn mcbdb metal double door with provision for fpmcb/isolator/rccb/rcbo as incomer and sp mcbs as outgoing inclusive of busbar,neutral bar,earth bar & two earth terminals etc. complete as per is:13032 (exclusive of mcb & isolator ): 8 way (8+24), 8 sq.mm multistrand pvc insulated copper wire bundle 90mtr, 1.sq.mm aluminium single core wire bundle of 100mtr. isi marked, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 2-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 4-core isi marked with alu. stranded/solid conductor: 16 sq.mm unarmoured, xlpe insulated power cable( conforming is-7098 part-1) 1100 volt grade 1-core isi marked with alu. stranded/solid conductor: 25sq.mm unarmoured, wooden ladder 21ft, toolkit set consisting of different sizes l-keys, screw drivers, testers and plier set., taperoll box consisting of 30pcs (conforms to is: 7809 (part 3, sec 1),self extinguishing,protects from electrolytic corrosion,excellent water resistance,suitable for primary ins
Tender For auction sale of depot miscellaneous scrap - scrap light weight elctrical accessories/domestic electrical appliances such as cfl, led bulb, electrical fittings, switch, socket junction box, speedy box, rgr, condencer, capacitor, electric house meter, jtb, rotatory switch, fuse, pressure gauge,fl fitting, power switch/socket, ceilling rose, electronic regulators, different types of mcb, lcb and its boxes, change-over, tube light, led tube light, led street light fitting, led tube light fittings, main switch, d.p switch, integrated circuit plates, switches, d.p box, all types of button/angle holder, pendent holder, train light fitting, birth light, head light, fitting, solar pannels, coach pannel board, lighting board, small battery/mobile charger, adaptor, hand loud speaker, disconnecting and earthing device with/without negligible nf attachememnt in different sort and sizes and other various known/unknown items which comes under electrical accessories/appliances. inculiding also some broken, rusted and poor condition items. not fit for railway use. location: - beside godown no-98/13 lbpl, dbaw, gst-18%, tcs -1% , hsn code-72044900 , allocation-20714208
Tender For supply of material and execution of indoor & outdoor signal and telecom work for provision of electronic interlocking-msdac based absolute block signaling system between merta road jn and ras station inconnection with new line of mtd-ras section of jodhpur division of north western railway. the work involves provision of new electronic interlocking at new merta city, dhaneria, jas nagar, katyasani, bhumbhaliya, stations and modification in existing hitachi make ei at merta road jn, existing kyosan make ei at ras station. provision of msdac along with associated works like trenching & laying of signalling and telecomcables in pre-fabricated ducts/dwc/gi pipes, supply-installation ofpoint machines, apparatus cases, signals, track circuit equipment,earthing material, data loggers, eld, fuse alarms, fire alarms,passenger amenity telecom items etc